Tenderwize
Zurück zur Suche

Supply of extracorporeal circulation devices

A.O.U. POLICLINICO FEDERICO II·Napoli, Italy·EUR 7.1M·Deadline Jul 03, 2026 · 9 days left·Open·Supplies·Framework
High value
Original notice title

GARA 1461/2026 - PROCEDURA APERTA PER LA CONCLUSIONE DI UN ACCORDO QUADRO PER L'AFFIDAMENTO DELLA LA FORNITURA DI DISPOSITIVI PER PER CIRCOLAZIONE EXTRACORPOREA CEC

65/100

Opportunity Score

Needs reviewHigh complexity
SuppliesFrameworkOpen
Why this score?

Opportunity

65 / 100

Complexity

80 / 100

Risk factors

Full procurement documents are not available in the provided data; critical technical specifications and contractual te...

63 lots with specific technical requirements (e.g., oxygenator flow rates, circuit designs) increase bid preparation co...

Submission deadline in 9 days

Deep Portfolio Analysis

Deep Company Fit Analysis

Uses:

  • Description
  • Industries & Services
  • Capabilities
  • Market & Experience
  • Certifications

Overview

Moderate opportunity

Key Facts

  • EUR 7.1M estimated value
  • Framework procurement
  • Supplies contract
  • 3 lots
  • Duration 1460 DAY
  • Supply of various extracorporeal circulation devices (CEC) for cardiac surgery.
  • 63 product lots covering oxygenators, circuits, cannulas, and related devices.
Show full summary

Open tender for a 4-year framework agreement with a single operator for the supply of extracorporeal circulation devices (CEC) for A.O.U. Federico II of Naples. The tender is divided into 63 product lots with a total estimated value of €7,062,504.85. Electronic submission is required, and all communication must be in Italian.

Risks

Full procurement documents are not available in the provided data; critical technical specifications and contractual te...

63 lots with specific technical requirements (e.g., oxygenator flow rates, circuit designs) increase bid preparation co...

Submission deadline in 9 days

Analysis may be incomplete

Only part of the procurement documentation was analyzed. Additional eligibility requirements, certificates, or submission documents may exist in the remaining tender documentation.

Key Requirements

Technical

  • Tenders must be in Italian (ITA).
  • Deadline for receipt of tenders: 17 July 2026, 10:00 (CEST).

Administrative

Award Criteria

Lot 1

Offerta economicamente più vantaggiosa

Lot 2

Offerta economicamente più vantaggiosa

Lot 3

Offerta economicamente più vantaggiosa

Lot 4

Offerta economicamente più vantaggiosa

Lot 5

Offerta economicamente più vantaggiosa

Lot 6

Offerta economicamente più vantaggiosa

Lot 7

Offerta economicamente più vantaggiosa

Lot 8

Offerta economicamente più vantaggiosa

Lot 9

Offerta economicamente più vantaggiosa

Lot 10

Offerta economicamente più vantaggiosa

Lot 11

Offerta economicamente più vantaggiosa

Lot 12

Offerta economicamente più vantaggiosa

Lot 13

Offerta economicamente più vantaggiosa

Lot 14

Offerta economicamente più vantaggiosa

Lot 15

Offerta economicamente più vantaggiosa

Lot 16

Offerta economicamente più vantaggiosa

Lot 17

Offerta economicamente più vantaggiosa

Lot 18

Offerta economicamente più vantaggiosa

Lot 19

Offerta economicamente più vantaggiosa

Lot 20

Offerta economicamente più vantaggiosa

Lot 21

Offerta economicamente più vantaggiosa

Lot 22

Offerta economicamente più vantaggiosa

Lot 23

Offerta economicamente più vantaggiosa

Lot 24

Offerta economicamente più vantaggiosa

Lot 25

Offerta economicamente più vantaggiosa

Lot 26

Offerta economicamente più vantaggiosa

Lot 27

Offerta economicamente più vantaggiosa

Lot 28

Offerta economicamente più vantaggiosa

Lot 29

Offerta economicamente più vantaggiosa

Lot 30

Offerta economicamente più vantaggiosa

Lot 31

Offerta economicamente più vantaggiosa

Lot 32

Offerta economicamente più vantaggiosa

Lot 33

Offerta economicamente più vantaggiosa

Lot 34

Offerta economicamente più vantaggiosa

Lot 35

Offerta economicamente più vantaggiosa

Lot 36

Offerta economicamente più vantaggiosa

Lot 37

Offerta economicamente più vantaggiosa

Lot 38

Offerta economicamente più vantaggiosa

Lot 39

Offerta economicamente più vantaggiosa

Lot 40

Offerta economicamente più vantaggiosa

Lot 41

Offerta economicamente più vantaggiosa

Lot 42

Offerta economicamente più vantaggiosa

Lot 43

Offerta economicamente più vantaggiosa

Lot 44

Offerta economicamente più vantaggiosa

Lot 45

Offerta economicamente più vantaggiosa

Lot 46

Offerta economicamente più vantaggiosa

Lot 47

Offerta economicamente più vantaggiosa

Lot 48

Offerta economicamente più vantaggiosa

Lot 49

Offerta economicamente più vantaggiosa

Lot 50

Offerta economicamente più vantaggiosa

Lot 51

Offerta economicamente più vantaggiosa

Lot 52

Offerta economicamente più vantaggiosa

Lot 53

Offerta economicamente più vantaggiosa

Lot 54

Offerta economicamente più vantaggiosa

Lot 55

Offerta economicamente più vantaggiosa

Lot 56

Offerta economicamente più vantaggiosa

Lot 57

Offerta economicamente più vantaggiosa

Lot 58

Offerta economicamente più vantaggiosa

Lot 59

Offerta economicamente più vantaggiosa

Lot 60

Offerta economicamente più vantaggiosa

Lot 61

Offerta economicamente più vantaggiosa

Lot 62

Offerta economicamente più vantaggiosa

Lot 63

Offerta economicamente più vantaggiosa

Buyer

Name

A.O.U. POLICLINICO FEDERICO II

Location

Napoli, ITA

Identifier

06909360635

Lots (63)

LOT-0001

Ossigenatori che consentano flussi di perfusione da 0 a 7 lt/m'/m", a membrana a fibre cave in polimetilpentene con trattamento biocompatibile, con scambiatore di calore ad alta efficienza , certificato per un utilizzo non inferiore a 14 giorni.

Oxygenators for perfusion flows 0-7 L/min, polymethylpentene hollow fiber membrane with biocompatible treatment, high-efficiency heat exchanger, certified for at least 14 days use.

SuppliesFrameworkEU fundedElectronic submission

EUR 58k

Estimated value

Location

ITF33, Italy

Duration

1460 DAY

Category

Extracorporeal circulatory unit

Selection criteria

Quality

Deadline

Deadline Jul 17, 2026

LOT-0002

Circuito per ECMO adulti preassemblato con ossigenatore in polimetilpentene e centrifuga compatibile con postazione ECMO in dotazione. Il circuito, con trattamento eparinico, deve essere certificato per un utilizzo non inferiore a 14 (quattordici) giorni.

Preassembled ECMO circuit for adults with polymethylpentene oxygenator and centrifugal pump compatible with existing ECMO station, heparin treatment, certified for at least 14 days use.

SuppliesFrameworkEU fundedElectronic submission

EUR 461.1k

Estimated value

Location

ITF33, Italy

Duration

1460 DAY

Category

Extracorporeal circulatory unit

Selection criteria

Quality

Deadline

Deadline Jul 17, 2026

LOT-0003

Ossigenatori che consentano flussi di perfusione da 0 a 7 lt/m'/m", a membrana a fibre cave in polipropilene con trattamento biocompatibile, filtro integrato e ridotto volume di riempimento, con scambiatore di calore e cardiotomo rigido con alta riserva ematica

Oxygenators for perfusion flows 0-7 L/min, polypropylene hollow fiber membrane with biocompatible treatment, integrated filter, low priming volume, heat exchanger, rigid cardiotomy with high blood reserve.

SuppliesFrameworkEU fundedElectronic submission

EUR 870k

Estimated value

Location

ITF33, Italy

Duration

1460 DAY

Category

Extracorporeal circulatory unit

Selection criteria

Quality

Deadline

Deadline Jul 17, 2026

LOT-0004

Ossigenatori che consentano flussi di perfusione da 0 a 8 lt/m'/m", a membrana a fibre cave in polipropilene con trattamento biocompatibile, filtro integrato e ridotto volume di riempimento, con scambiatore di calore e cardiotomo rigido con alta riserva ematica.

Ossigenatori che consentano flussi di perfusione da 0 a 8 lt/m'/m", a membrana a fibre cave in polipropilene con trattamento biocompatibile, filtro integrato e ridotto volume di riempimento, con scambiatore di calore e cardiotomo rigido con alta riserva ematica.

SuppliesFrameworkEU fundedElectronic submission

EUR 116k

Estimated value

Location

ITF33, Italy

Duration

1460 DAY

Category

Extracorporeal circulatory unit

Selection criteria

Quality

LOT-0005

Ossigenatori che consentano flussi di perfusione da 0 a 7 lt/m'/m" a membrana a fibre cave in polipropilene con trattamento biocompatibile, filtro integrato e ridotto volume di riempimento, con scambiatore di calore e cardiotomo rigido con alta riserva ematica e possibilità di separare il sangue venoso da quello aspirato.

Ossigenatori che consentano flussi di perfusione da 0 a 7 lt/m'/m" a membrana a fibre cave in polipropilene con trattamento biocompatibile, filtro integrato e ridotto volume di riempimento, con scambiatore di calore e cardiotomo rigido con alta riserva ematica e possibilità di separare il sangue venoso da quello aspirato.

SuppliesFrameworkEU fundedElectronic submission

EUR 87k

Estimated value

Location

ITF33, Italy

Duration

1460 DAY

Category

Extracorporeal circulatory unit

Selection criteria

Quality

LOT-0006

Ossigenatori small-adult che consentano flussi di perfusione da 0 a 5 lt/m'/m", a membrana a fibre cave in polipropilene con trattamento biocompatibile, filtro integrato e ridotto volume di riempimento, con scambiatore di calore e cardiotomo rigido con alta riserva ematica .

Ossigenatori small-adult che consentano flussi di perfusione da 0 a 5 lt/m'/m", a membrana a fibre cave in polipropilene con trattamento biocompatibile, filtro integrato e ridotto volume di riempimento, con scambiatore di calore e cardiotomo rigido con alta riserva ematica .

SuppliesFrameworkEU fundedElectronic submission

EUR 87k

Estimated value

Location

ITF33, Italy

Duration

1460 DAY

Category

Extracorporeal circulatory unit

Selection criteria

Quality

LOT-0007

Circuito per perfusione selettiva cerebrale secondo disegno fornito dal centro (allegato 2)

Circuito per perfusione selettiva cerebrale secondo disegno fornito dal centro (allegato 2)

SuppliesFrameworkEU fundedElectronic submission

EUR 14.5k

Estimated value

Location

ITF33, Italy

Duration

1460 DAY

Category

Extracorporeal circulatory unit

Selection criteria

Quality

LOT-0008

Circuiti per cardioplegia cristalloide con ricircolo, completi di serpentina metallica, cardiotomo pediatrico e filtro secondo disegno fornito dal centro (allegato 3)

Circuiti per cardioplegia cristalloide con ricircolo, completi di serpentina metallica, cardiotomo pediatrico e filtro secondo disegno fornito dal centro (allegato 3)

SuppliesFrameworkEU fundedElectronic submission

EUR 348k

Estimated value

Location

ITF33, Italy

Duration

1460 DAY

Category

Extracorporeal circulatory unit

Selection criteria

Quality

LOT-0009

Circuito per drenaggio venoso assistito secondo disegno fornito dal centro (allegato 4)

Circuito per drenaggio venoso assistito secondo disegno fornito dal centro (allegato 4)

SuppliesFrameworkEU fundedElectronic submission

EUR 81.2k

Estimated value

Location

ITF33, Italy

Duration

1460 DAY

Category

Extracorporeal circulatory unit

Selection criteria

Quality

LOT-0010

Circuito per aspirazioni trombi completo di filtro e cannula a tulipano 23Fr.

Circuito per aspirazioni trombi completo di filtro e cannula a tulipano 23Fr.

SuppliesFrameworkEU fundedElectronic submission

EUR 870k

Estimated value

Location

ITF33, Italy

Duration

1460 DAY

Category

Extracorporeal circulatory unit

Selection criteria

Quality

LOT-0011

Cannule arteriose con struttura flessibile in PVC punta rigida curva ed anello di fissaggio con connettore e luer lock:mis 20, 22, 24 Fr.

Cannule arteriose con struttura flessibile in PVC punta rigida curva ed anello di fissaggio con connettore e luer lock:mis 20, 22, 24 Fr.

SuppliesFrameworkEU fundedElectronic submission

EUR 34.8k

Estimated value

Location

ITF33, Italy

Duration

1460 DAY

Category

Extracorporeal circulatory unit

Selection criteria

Quality

LOT-0012

Cannule arteriose con struttura flessibile in PVC punta rigida retta ed anello di fissaggio con connettore e luer lock : mis 20,22, 24 Fr.

Cannule arteriose con struttura flessibile in PVC punta rigida retta ed anello di fissaggio con connettore e luer lock : mis 20,22, 24 Fr.

SuppliesFrameworkEU fundedElectronic submission

EUR 104.4k

Estimated value

Location

ITF33, Italy

Duration

1460 DAY

Category

Extracorporeal circulatory unit

Selection criteria

Quality

LOT-0013

Cannule arteriose con struttura flessibile in PVC punta rigida retta ed anello di fissaggio con connettore e luer lock : mis 16,18 Fr.

Cannule arteriose con struttura flessibile in PVC punta rigida retta ed anello di fissaggio con connettore e luer lock : mis 16,18 Fr.

SuppliesFrameworkEU fundedElectronic submission

EUR 11.6k

Estimated value

Location

ITF33, Italy

Duration

1460 DAY

Category

Extracorporeal circulatory unit

Selection criteria

Quality

LOT-0014

Cannule arteriose armate sottili per interventi di chirurgia mininvasiva munite di anello di sutura radiopaco regolabile, introduttore, tappo emostatico e tappo di sfiato. Misure da 18Fr a 24Fr.

Cannule arteriose armate sottili per interventi di chirurgia mininvasiva munite di anello di sutura radiopaco regolabile, introduttore, tappo emostatico e tappo di sfiato. Misure da 18Fr a 24Fr.

SuppliesFrameworkEU fundedElectronic submission

EUR 50.2k

Estimated value

Location

ITF33, Italy

Duration

1460 DAY

Category

Extracorporeal circulatory unit

Selection criteria

Quality

LOT-0015

Cannule arteriose in PVC flessibile provviste di mandrino per perfusione femorale ed incannulazione percutanea adulte da 18Fr. a 25Fr.

Cannule arteriose in PVC flessibile provviste di mandrino per perfusione femorale ed incannulazione percutanea adulte da 18Fr. a 25Fr.

SuppliesFrameworkEU fundedElectronic submission

EUR 87k

Estimated value

Location

ITF33, Italy

Duration

1460 DAY

Category

Extracorporeal circulatory unit

Selection criteria

Quality

LOT-0016

Kit per inserzione percutanea provvisto di ago,guide,dilatatori con calibro progressivo per la cannulazione percutanea dell' arteria femorale.

Kit per inserzione percutanea provvisto di ago,guide,dilatatori con calibro progressivo per la cannulazione percutanea dell' arteria femorale.

SuppliesFrameworkEU fundedElectronic submission

EUR 29k

Estimated value

Location

ITF33, Italy

Duration

1460 DAY

Category

Extracorporeal circulatory unit

Selection criteria

Quality

LOT-0017

Cannule venose cavali con struttura in PVC flessibile, armata e malleabile con punta a canestrello e foro centrale, misure da 24Fr, a 34Fr.

Cannule venose cavali con struttura in PVC flessibile, armata e malleabile con punta a canestrello e foro centrale, misure da 24Fr, a 34Fr.

SuppliesFrameworkEU fundedElectronic submission

EUR 46.4k

Estimated value

Location

ITF33, Italy

Duration

1460 DAY

Category

Extracorporeal circulatory unit

Selection criteria

Quality

LOT-0018

Cannule venose cavali con struttura in PVC flessibile, armata con punta a canestrello e foro centrale, misure da 24Fr, a 34Fr.

Cannule venose cavali con struttura in PVC flessibile, armata con punta a canestrello e foro centrale, misure da 24Fr, a 34Fr.

SuppliesFrameworkEU fundedElectronic submission

EUR 23.2k

Estimated value

Location

ITF33, Italy

Duration

1460 DAY

Category

Extracorporeal circulatory unit

Selection criteria

Quality

LOT-0019

Cannule venose con struttura in PVC flessibile ed armata con punta metallica angolata a 90° mis. da 18 a 24Fr per raccordo 3/8.

Cannule venose con struttura in PVC flessibile ed armata con punta metallica angolata a 90° mis. da 18 a 24Fr per raccordo 3/8.

SuppliesFrameworkEU fundedElectronic submission

EUR 46.4k

Estimated value

Location

ITF33, Italy

Duration

1460 DAY

Category

Extracorporeal circulatory unit

Selection criteria

Quality

LOT-0020

Monocannula venosa doppio stadio atrio-cavale armata con parete sottile ad alta flessibilità con connettore . Varie misure da 28-36Fr; 32-40Fr; 36-50Fr .

Monocannula venosa doppio stadio atrio-cavale armata con parete sottile ad alta flessibilità con connettore . Varie misure da 28-36Fr; 32-40Fr; 36-50Fr .

SuppliesFrameworkEU fundedElectronic submission

EUR 46.4k

Estimated value

Location

ITF33, Italy

Duration

1460 DAY

Category

Extracorporeal circulatory unit

Selection criteria

Quality

LOT-0021

Monocannula venose doppio stadio atrio-cavale armata con parete sottile ad alta flessibilità e profilo schiacciato per ridotto ingombro con connettore mis. 36-46 , 32-40 e 28-36.

Monocannula venose doppio stadio atrio-cavale armata con parete sottile ad alta flessibilità e profilo schiacciato per ridotto ingombro con connettore mis. 36-46 , 32-40 e 28-36.

SuppliesFrameworkEU fundedElectronic submission

EUR 23.2k

Estimated value

Location

ITF33, Italy

Duration

1460 DAY

Category

Extracorporeal circulatory unit

Selection criteria

Quality

LOT-0022

Cannula venosa armata a tre stadi a profilo ridotto per mininvasiva completo di Kit per inserzione percutanea provvisto di ago,guide,dilatatori con calibro progressivo compatibile con la cannulazione percutanea. Misure varie

Cannula venosa armata a tre stadi a profilo ridotto per mininvasiva completo di Kit per inserzione percutanea provvisto di ago,guide,dilatatori con calibro progressivo compatibile con la cannulazione percutanea. Misure varie

SuppliesFrameworkEU fundedElectronic submission

EUR 7.5k

Estimated value

Location

ITF33, Italy

Duration

1460 DAY

Category

Extracorporeal circulatory unit

Selection criteria

Quality

LOT-0023

Cannule venose femorali adulte con struttura in PVC flessibile provviste di mandrino per incannulazione percutanea. Misure varie

Cannule venose femorali adulte con struttura in PVC flessibile provviste di mandrino per incannulazione percutanea. Misure varie

SuppliesFrameworkEU fundedElectronic submission

EUR 130.5k

Estimated value

Location

ITF33, Italy

Duration

1460 DAY

Category

Extracorporeal circulatory unit

Selection criteria

Quality

LOT-0024

Cannule venose femorali bicavali con struttura in PVC flessibile provviste di mandrino per incannulazione percutanea misure varie.

Cannule venose femorali bicavali con struttura in PVC flessibile provviste di mandrino per incannulazione percutanea misure varie.

SuppliesFrameworkEU fundedElectronic submission

EUR 52.2k

Estimated value

Location

ITF33, Italy

Duration

1460 DAY

Category

Extracorporeal circulatory unit

Selection criteria

Quality

LOT-0025

Kit per inserzione percutanea provvisto di ago,guide,dilatatori con calibro progressivo per la cannulazione percutanea della vena femorale.

Kit per inserzione percutanea provvisto di ago,guide,dilatatori con calibro progressivo per la cannulazione percutanea della vena femorale.

SuppliesFrameworkEU fundedElectronic submission

EUR 29k

Estimated value

Location

ITF33, Italy

Duration

1460 DAY

Category

Extracorporeal circulatory unit

Selection criteria

Quality

LOT-0026

Cannule venose giugulare per adulti introduttore e tappo emostatico, misure varie

Cannule venose giugulare per adulti introduttore e tappo emostatico, misure varie

SuppliesFrameworkEU fundedElectronic submission

EUR 26.1k

Estimated value

Location

ITF33, Italy

Duration

1460 DAY

Category

Extracorporeal circulatory unit

Selection criteria

Quality

LOT-0027

Cannule venose femorali ad alto flusso autoespandibili realizzate con rete metallica, misure varie

Cannule venose femorali ad alto flusso autoespandibili realizzate con rete metallica, misure varie

SuppliesFrameworkEU fundedElectronic submission

EUR 139.2k

Estimated value

Location

ITF33, Italy

Duration

1460 DAY

Category

Extracorporeal circulatory unit

Selection criteria

Quality

LOT-0028

Kit per inserzione percutanea delle cannule femorali ad alto flusso autoespandibili con rete metallica, composto da ago, filo guida, dilatatori.

Kit per inserzione percutanea delle cannule femorali ad alto flusso autoespandibili con rete metallica, composto da ago, filo guida, dilatatori.

SuppliesFrameworkEU fundedElectronic submission

EUR 20.9k

Estimated value

Location

ITF33, Italy

Duration

1460 DAY

Category

Extracorporeal circulatory unit

Selection criteria

Quality

LOT-0029

Cannule in PVC flessibile con mandrino per somministrazione della cardioplegia coronarica per via retrograda attraverso il seno coronarico con fori nella parte distale e palloncino gonfiabile manualmente . Misura varie

Cannule in PVC flessibile con mandrino per somministrazione della cardioplegia coronarica per via retrograda attraverso il seno coronarico con fori nella parte distale e palloncino gonfiabile manualmente . Misura varie

SuppliesFrameworkEU fundedElectronic submission

EUR 19.1k

Estimated value

Location

ITF33, Italy

Duration

1460 DAY

Category

Extracorporeal circulatory unit

Selection criteria

Quality

LOT-0030

Cannula a doppio lume giugulare per ECMO veno-venoso .Misure varie

Cannula a doppio lume giugulare per ECMO veno-venoso .Misure varie

SuppliesFrameworkEU fundedElectronic submission

EUR 230.6k

Estimated value

Location

ITF33, Italy

Duration

1460 DAY

Category

Extracorporeal circulatory unit

Selection criteria

Quality

LOT-0031

Cannula a doppio lume sterile per la perfusione cerebrale anterograda selettiva. Il lume principale è il condotto per l’infusione di sangue dal circuito per circolazione extracorporea al cervello il secondo lume consta in una linea di gonfiaggio del palloncino di posizionamento posto all’estremità distale della cannula. Mis. 14-17-20 Fr.

Cannula a doppio lume sterile per la perfusione cerebrale anterograda selettiva. Il lume principale è il condotto per l’infusione di sangue dal circuito per circolazione extracorporea al cervello il secondo lume consta in una linea di gonfiaggio del palloncino di posizionamento posto all’estremità distale della cannula. Mis. 14-17-20 Fr.

SuppliesFrameworkEU fundedElectronic submission

EUR 58k

Estimated value

Location

ITF33, Italy

Duration

1460 DAY

Category

Extracorporeal circulatory unit

Selection criteria

Quality

LOT-0032

Adattatore in PVC flessibile per cardioplegia a Y con raccordo femmina-maschio-maschio.

Adattatore in PVC flessibile per cardioplegia a Y con raccordo femmina-maschio-maschio.

SuppliesFrameworkEU fundedElectronic submission

EUR 5.8k

Estimated value

Location

ITF33, Italy

Duration

1460 DAY

Category

Extracorporeal circulatory unit

Selection criteria

Quality

LOT-0033

Prolunghe da 120cm di lunghezza , 2,5x4,1mm di diametro con raccordi luer-lock maschio/ luer-lock maschio fornito in confezione singola

Prolunghe da 120cm di lunghezza , 2,5x4,1mm di diametro con raccordi luer-lock maschio/ luer-lock maschio fornito in confezione singola

SuppliesFrameworkEU fundedElectronic submission

EUR 1.9k

Estimated value

Location

ITF33, Italy

Duration

1460 DAY

Category

Extracorporeal circulatory unit

Selection criteria

Quality

LOT-0034

Cannula bilume per assistenza ventricolare destra che consenta un drenaggio atriale destro e un outflow in arteria polmonare

Cannula bilume per assistenza ventricolare destra che consenta un drenaggio atriale destro e un outflow in arteria polmonare

SuppliesFrameworkEU fundedElectronic submission

EUR 319k

Estimated value

Location

ITF33, Italy

Duration

1460 DAY

Category

Extracorporeal circulatory unit

Selection criteria

Quality

LOT-0035

Sistema di catetere da 9Fr con micro pompa assiale da 19Fr dotato di sensore ottico per il monitoraggio della posizione per assistenza ventricolare sinistra...

Sistema di catetere da 9Fr con micro pompa assiale da 19Fr dotato di sensore ottico per il monitoraggio della posizione per assistenza ventricolare sinistra...

SuppliesFrameworkEU fundedElectronic submission

EUR 464k

Estimated value

Location

ITF33, Italy

Duration

1460 DAY

Category

Extracorporeal circulatory unit

Selection criteria

Quality

LOT-0036

Cannule per ostio coronarico morbide con palloncino autogonfiante. Varie misure.

Cannule per ostio coronarico morbide con palloncino autogonfiante. Varie misure.

SuppliesFrameworkEU fundedElectronic submission

EUR 38.7k

Estimated value

Location

ITF33, Italy

Duration

1460 DAY

Category

Extracorporeal circulatory unit

Selection criteria

Quality

LOT-0037

Cannule per la somministrazione di soluzione cardioplegica per via anterograda direttamente attraverso gli osti coronarici, munita di corpo centrale malleabile in acciaio inossidabile, dotata di puntale in gel di silicone morbido a forma concava per la cannulazione atraumatica delle coronarie.Varie misure

Cannule per la somministrazione di soluzione cardioplegica per via anterograda direttamente attraverso gli osti coronarici, munita di corpo centrale malleabile in acciaio inossidabile, dotata di puntale in gel di silicone morbido a forma concava per la cannulazione atraumatica delle coronarie.Varie misure

SuppliesFrameworkEU fundedElectronic submission

EUR 58k

Estimated value

Location

ITF33, Italy

Duration

1460 DAY

Category

Extracorporeal circulatory unit

Selection criteria

Quality

LOT-0038

Catetere aspirazione ventricolare in pvc, (10, 13, 16 e 20fr, 33cm e 40,6cm), con punta angolata ed estremità a cono per facilitare l'inserimento, monouso sterile. Il grado di aspirazione deve essere monitorato per ridurre la possibilità di embolia gassosa.

Catetere aspirazione ventricolare in pvc, (10, 13, 16 e 20fr, 33cm e 40,6cm), con punta angolata ed estremità a cono per facilitare l'inserimento, monouso sterile. Il grado di aspirazione deve essere monitorato per ridurre la possibilità di embolia gassosa.

SuppliesFrameworkEU fundedElectronic submission

EUR 34.8k

Estimated value

Location

ITF33, Italy

Duration

1460 DAY

Category

Extracorporeal circulatory unit

Selection criteria

Quality

LOT-0039

Catetere aspirazione ventricolare in silicone, (10, 13, 16 e 20fr, 33cm e 40,6cm), con introduttore malleabile monouso sterile. Il filo malleabile permette la sagomatura precisa e una facilità di inserimento. Il grado di aspirazione deve essere monitorato per ridurre la possibilità di embolia gassosa

Catetere aspirazione ventricolare in silicone, (10, 13, 16 e 20fr, 33cm e 40,6cm), con introduttore malleabile monouso sterile. Il filo malleabile permette la sagomatura precisa e una facilità di inserimento. Il grado di aspirazione deve essere monitorato per ridurre la possibilità di embolia gassosa

SuppliesFrameworkEU fundedElectronic submission

EUR 19.3k

Estimated value

Location

ITF33, Italy

Duration

1460 DAY

Category

Extracorporeal circulatory unit

Selection criteria

Quality

LOT-0040

Catetere aspiratore pericardico in tubo flessibile o malleabile, con connettore da ¾, 20 Fr, lunghezza circa 40 cm, monouso, sterile con punta avvolta da una molla in metallo appesantita che termina con punta metallica arrotondata

Catetere aspiratore pericardico in tubo flessibile o malleabile, con connettore da ¾, 20 Fr, lunghezza circa 40 cm, monouso, sterile con punta avvolta da una molla in metallo appesantita che termina con punta metallica arrotondata

SuppliesFrameworkEU fundedElectronic submission

EUR 38.7k

Estimated value

Location

ITF33, Italy

Duration

1460 DAY

Category

Extracorporeal circulatory unit

Selection criteria

Quality

LOT-0041

Sottopompa in silicone in confezione singola : mis. 1/4 -3 /8 - 1/2

Sottopompa in silicone in confezione singola : mis. 1/4 -3 /8 - 1/2

SuppliesFrameworkEU fundedElectronic submission

EUR 2.6k

Estimated value

Location

ITF33, Italy

Duration

1460 DAY

Category

Extracorporeal circulatory unit

Selection criteria

Quality

LOT-0042

Tubi sterili in PVC in confezione singola lunghezza 1 metro di calibro variabile (3/8, 1/2, 1/4).

Tubi sterili in PVC in confezione singola lunghezza 1 metro di calibro variabile (3/8, 1/2, 1/4).

SuppliesFrameworkEU fundedElectronic submission

EUR 2.6k

Estimated value

Location

ITF33, Italy

Duration

1460 DAY

Category

Extracorporeal circulatory unit

Selection criteria

Quality

LOT-0043

Sacche sterili non anticoagulate per il recupero di sangue dai circuito extracorporeo di capacità non inferiore a 1000 ml.

Sacche sterili non anticoagulate per il recupero di sangue dai circuito extracorporeo di capacità non inferiore a 1000 ml.

SuppliesFrameworkEU fundedElectronic submission

EUR 5.8k

Estimated value

Location

ITF33, Italy

Duration

1460 DAY

Category

Extracorporeal circulatory unit

Selection criteria

Quality

LOT-0044

Sistema di vapor trap in grado di trattenere la condensa del gas escape dell'ossigenatore evitando che entri a contatto con il capnografo del sistema diagnostico ottimizzando la lettura della FeCO2

Sistema di vapor trap in grado di trattenere la condensa del gas escape dell'ossigenatore evitando che entri a contatto con il capnografo del sistema diagnostico ottimizzando la lettura della FeCO2

SuppliesFrameworkEU fundedElectronic submission

EUR 11.6k

Estimated value

Location

ITF33, Italy

Duration

1460 DAY

Category

Extracorporeal circulatory unit

Selection criteria

Quality

LOT-0045

Sistema per emofiltrazione arterovenosa continua pediatrica composto da filtro e circuito

Sistema per emofiltrazione arterovenosa continua pediatrica composto da filtro e circuito

SuppliesFrameworkEU fundedElectronic submission

EUR 23.2k

Estimated value

Location

ITF33, Italy

Duration

1460 DAY

Category

Extracorporeal circulatory unit

Selection criteria

Quality

LOT-0046

Kit per emoconcentrazione prelavato, con membrana in polisulfone, massima efficienza di scambio, con priming max non superiore a 100 ml, con sacca di scarto graduata di capacità di almeno 2 litri e linee per l’utilizzo durante circolazione extracorporea.

Kit per emoconcentrazione prelavato, con membrana in polisulfone, massima efficienza di scambio, con priming max non superiore a 100 ml, con sacca di scarto graduata di capacità di almeno 2 litri e linee per l’utilizzo durante circolazione extracorporea.

SuppliesFrameworkEU fundedElectronic submission

EUR 116k

Estimated value

Location

ITF33, Italy

Duration

1460 DAY

Category

Extracorporeal circulatory unit

Selection criteria

Quality

LOT-0047

Connettori sterili per CEC misure varie retti in confezioni singole con e senza luer-lock

Connettori sterili per CEC misure varie retti in confezioni singole con e senza luer-lock

SuppliesFrameworkEU fundedElectronic submission

EUR 19.3k

Estimated value

Location

ITF33, Italy

Duration

1460 DAY

Category

Extracorporeal circulatory unit

Selection criteria

Quality

LOT-0048

Connettori sterili per CEC misure varie ad Y in confezioni singole con e senza attacco luer-lock

Connettori sterili per CEC misure varie ad Y in confezioni singole con e senza attacco luer-lock

SuppliesFrameworkEU fundedElectronic submission

EUR 19.3k

Estimated value

Location

ITF33, Italy

Duration

1460 DAY

Category

Extracorporeal circulatory unit

Selection criteria

Quality

LOT-0049

Cannule arteriose in puliuretano,armate,percutanee,certificate per utilizzo non inferiore ai 30 giorni : misure varie

Cannule arteriose in puliuretano,armate,percutanee,certificate per utilizzo non inferiore ai 30 giorni : misure varie

SuppliesFrameworkEU fundedElectronic submission

EUR 50k

Estimated value

Location

ITF33, Italy

Duration

1460 DAY

Category

Extracorporeal circulatory unit

Selection criteria

Quality

LOT-0050

Cannule venose in puliuretano,armate,percutanee,certificate per utilizzo non inferiore ai 30 giorni : misure varie

Cannule venose in puliuretano,armate,percutanee,certificate per utilizzo non inferiore ai 30 giorni : misure varie

SuppliesFrameworkEU fundedElectronic submission

EUR 50k

Estimated value

Location

ITF33, Italy

Duration

1460 DAY

Category

Extracorporeal circulatory unit

Selection criteria

Quality

LOT-0051

Cannula per la somministrazione di soluzione cardioplegica per via anterograda caratterizzata da punta radiopaca , corpi trasparente e linea per il vent separata , con introduttore di sicurezza e con profondità di inserimento nell'aorta. Più misure

Cannula per la somministrazione di soluzione cardioplegica per via anterograda caratterizzata da punta radiopaca , corpi trasparente e linea per il vent separata , con introduttore di sicurezza e con profondità di inserimento nell'aorta. Più misure

SuppliesFrameworkEU fundedElectronic submission

EUR 139.2k

Estimated value

Location

ITF33, Italy

Duration

1460 DAY

Category

Extracorporeal circulatory unit

Selection criteria

Quality

LOT-0052

Cannule per radice aortica caratterizzate da una punta radiopaca ,corpo trasparente ed introduttore di sicurezza , con sistema di retrazione , blocco e protezione dell'ago . Lunghezza 30 cm per accessi mininvasivi

Cannule per radice aortica caratterizzate da una punta radiopaca ,corpo trasparente ed introduttore di sicurezza , con sistema di retrazione , blocco e protezione dell'ago . Lunghezza 30 cm per accessi mininvasivi

SuppliesFrameworkEU fundedElectronic submission

EUR 9.6k

Estimated value

Location

ITF33, Italy

Duration

1460 DAY

Category

Extracorporeal circulatory unit

Selection criteria

Quality

LOT-0053

Adattatore per cardioplegia costituito da due linee in PVC convergenti a Y, lunghezza totale circa 19 cm e lunghezza dei due prolungamenti di circa 8 cm con connettore Luer Lock femmina e connettore da 1/4 per la linea vent , su entrambe le linee sono presenti clamp di colore differentei. La linea singola di collegamento alla linea per la cardioplegia è munita di un connettore Luer Lock maschio.

Adattatore per cardioplegia costituito da due linee in PVC convergenti a Y, lunghezza totale circa 19 cm e lunghezza dei due prolungamenti di circa 8 cm con connettore Luer Lock femmina e connettore da 1/4 per la linea vent , su entrambe le linee sono presenti clamp di colore differentei. La linea singola di collegamento alla linea per la cardioplegia è munita di un connettore Luer Lock maschio.

SuppliesFrameworkEU fundedElectronic submission

EUR 5.8k

Estimated value

Location

ITF33, Italy

Duration

1460 DAY

Category

Extracorporeal circulatory unit

Selection criteria

Quality

LOT-0054

Cannula aortica a dispersione di flusso con mandrino malleabile per accessi mininvasivi: misure varie

Cannula aortica a dispersione di flusso con mandrino malleabile per accessi mininvasivi: misure varie

SuppliesFrameworkEU fundedElectronic submission

EUR 92.8k

Estimated value

Location

ITF33, Italy

Duration

1460 DAY

Category

Extracorporeal circulatory unit

Selection criteria

Quality

LOT-0055

Cannula arteriosa multi accesso con meccanismo di inserzione atraumatico per cannulazione centrale, periferica e ascellare o femorale, eventuale drenaggio venoso giugulare percutaneo, senza scalino. Mis. 16-18-20-22 Fr.

Cannula arteriosa multi accesso con meccanismo di inserzione atraumatico per cannulazione centrale, periferica e ascellare o femorale, eventuale drenaggio venoso giugulare percutaneo, senza scalino. Mis. 16-18-20-22 Fr.

SuppliesFrameworkEU fundedElectronic submission

EUR 174k

Estimated value

Location

ITF33, Italy

Duration

1460 DAY

Category

Extracorporeal circulatory unit

Selection criteria

Quality

LOT-0056

Cannule per perfusione dell'aorta, armate con palloncino da 5 mm. nella parte distale per posizionamento e fissaggio della stessa cannula all'interno del vaso per prevenire un flusso retrogrado. Lunghezza40/50cm: misure da 20Fr.a 24F.

Cannule per perfusione dell'aorta, armate con palloncino da 5 mm. nella parte distale per posizionamento e fissaggio della stessa cannula all'interno del vaso per prevenire un flusso retrogrado. Lunghezza40/50cm: misure da 20Fr.a 24F.

SuppliesFrameworkEU fundedElectronic submission

EUR 16.9k

Estimated value

Location

ITF33, Italy

Duration

1460 DAY

Category

Extracorporeal circulatory unit

Selection criteria

Quality

LOT-0057

Kit per la cannulazione dell'arteria femorale in supporto all'ecmo composto da dilatatori ,otturatore e cannula arteriosa femorale bidirezionale per prevenire l'ischemia dell'arto inferiore.

Kit per la cannulazione dell'arteria femorale in supporto all'ecmo composto da dilatatori ,otturatore e cannula arteriosa femorale bidirezionale per prevenire l'ischemia dell'arto inferiore.

SuppliesFrameworkEU fundedElectronic submission

EUR 58k

Estimated value

Location

ITF33, Italy

Duration

1460 DAY

Category

Extracorporeal circulatory unit

Selection criteria

Quality

LOT-0058

Catetere a triplo lume per occlusione endoluminale dell'aorta per via percutanea transfemorale, rilascio della soluzione cardioplegica e venting della radice aortica . La confezione deve includere due siringhe per il riempimento del pallone , filo guida da 200cm ed una valvola per rilevare il vuoto.Misure varie

Catetere a triplo lume per occlusione endoluminale dell'aorta per via percutanea transfemorale, rilascio della soluzione cardioplegica e venting della radice aortica . La confezione deve includere due siringhe per il riempimento del pallone , filo guida da 200cm ed una valvola per rilevare il vuoto.Misure varie

SuppliesFrameworkEU fundedElectronic submission

EUR 156.6k

Estimated value

Location

ITF33, Italy

Duration

1460 DAY

Category

Extracorporeal circulatory unit

Selection criteria

Quality

LOT-0059

Cannula arteriosa femorale ,armata da 21e 23 Fr.con braccio laterale per introduttore di catetere per occlusione endoluminale aortica.Deve essere fornita assieme ad un mandrino che ne facilita l'inserzione per via chirurgica e ad un filo guida da 0,038''

Cannula arteriosa femorale ,armata da 21e 23 Fr.con braccio laterale per introduttore di catetere per occlusione endoluminale aortica.Deve essere fornita assieme ad un mandrino che ne facilita l'inserzione per via chirurgica e ad un filo guida da 0,038''

SuppliesFrameworkEU fundedElectronic submission

EUR 30.2k

Estimated value

Location

ITF33, Italy

Duration

1460 DAY

Category

Extracorporeal circulatory unit

Selection criteria

Quality

LOT-0060

Drenaggio toracico tipo jackson pratt

Drenaggio toracico tipo jackson pratt

SuppliesFrameworkEU fundedElectronic submission

EUR 14.5k

Estimated value

Location

ITF33, Italy

Duration

1460 DAY

Category

Extracorporeal circulatory unit

Selection criteria

Quality

LOT-0061

Sistema automatico di fissaggio a taglio sutura per approccio chirurgia mininvasiva , composto da uno stelo della lunghezza di 31 cm o di 14 cm, dello spessore di 4-5 mm, da un manipolo dotato di meccanismo di crimpaggio da un'asola di filo metallico e da una clip in titanio (fissatore).

Sistema automatico di fissaggio a taglio sutura per approccio chirurgia mininvasiva , composto da uno stelo della lunghezza di 31 cm o di 14 cm, dello spessore di 4-5 mm, da un manipolo dotato di meccanismo di crimpaggio da un'asola di filo metallico e da una clip in titanio (fissatore).

SuppliesFrameworkEU fundedElectronic submission

EUR 754k

Estimated value

Location

ITF33, Italy

Duration

1460 DAY

Category

Extracorporeal circulatory unit

Selection criteria

Quality

LOT-0062

Set per il monitoraggio della pressione cruenta monovia composto da trasduttore trasparente con rubinetto a 3 vie per lo zero integrato nel trasduttore per evitare sconnessioni accidentali

Set per il monitoraggio della pressione cruenta monovia composto da trasduttore trasparente con rubinetto a 3 vie per lo zero integrato nel trasduttore per evitare sconnessioni accidentali

SuppliesFrameworkEU fundedElectronic submission

EUR 87k

Estimated value

Location

ITF33, Italy

Duration

1460 DAY

Category

Extracorporeal circulatory unit

Selection criteria

Quality

LOT-0063

Box fissatori per dispositivo automatico di fissaggio e di taglio e sutura

Box fissatori per dispositivo automatico di fissaggio e di taglio e sutura

SuppliesFrameworkEU fundedElectronic submission

EUR 34.8k

Estimated value

Location

ITF33, Italy

Duration

1460 DAY

Category

Extracorporeal circulatory unit

Selection criteria

Quality

Procurement Details

Publication date
11 Jun 2026
Notice type
Contract notice — standard
Languages
Italian

Reference metadata

Notice subtype
16
Notice version
1
Legal basis
32014L0024

Reference IDs

Tender ID
404685-2026
Source notice ID
d95decab-a19b-4a33-839b-fbfc81d3409b

Documents (2)

Similar tenders